TS
2006
Loop Position
Infrared Product Positoning, Centering
Technical
Specifications
1. Mechanics
-Cast aluminum housing,
enclosure rated at IP 66
(NEMA 4, NEMA 12)
-Weight: 9 kg (approx 20 Ibs)
-Adjustable mounting foot with an 18 mm diameter
hole
-Dimensions: see diagram below
2. Optics
Angle
Model
|
Explored angle
|
TS 2016
TS 2036
TS 2056
|
10 degrees
30 degrees
50 degrees
|

- Spectral sensitivity: photocell, range from 1 to 3 µ , with
maximum sensitivity at 2.2 µ
- Range of material
temperature: dependant on the material to be
detected
For iron and
steel:
- from 400 °C (750 °F)
with the ordinary sensitivity
type
- from 250 °C (480 °F)
with the high sensitivity type.
NOTE: When the temperature
of the product is expected to always exceed 400°C
(750°F) it is not advisable to use the high sensitivity
model, as it might detect the scale or reflections. For
other materials such as copper, brass, alloys, glass,
etc., the temperature range is dependant on the
products infrared emissivity. Consult the factory
for these products.
- Optimal distances
between the sensor and different products:
| Wire 5 to12 mm |
Small bars 10 x 10 mm
to 40 x 40 mm |
|
Billet and small beam |
|
Bloom |
| Strip |
|
Sheet |
|
Heavy plate |
|
Slab |
|
| 0.20 to 3 m |
0.20 to 4 m
|
|
0.50 to 6 m |
|
over 2 |
| 0.60 to 2 m |
|
1.00 to 6 m |
|
1.00 to 8 m |
|
over 2 m |
|
 